Good conductivity and good resistance to high temperatures. Used for the electrodes of electrical resistance welding.
|
Chemical compound % |
Agent |
Cu |
Be |
Co |
Cr |
Fe |
Mn |
Ni |
Pb |
Si |
Zr |
Other |
Mass-volume g/cm3 |
Mini: |
Reste
|
-
|
-
|
0,5
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
8,9
|
Maxi: |
-
|
-
|
-
|
1,2
|
0,08
|
-
|
-
|
-
|
0,1
|
-
|
0,2
|
-
|
|
Mechanical properties of bars for general usings (EN 12163): |
State |
Implementation |
Diameter or size/flats mm |
Tensile strength Rm N/mm˛ min. |
Conventional elastic limit at 0,2 Rp0,2 N/mm² |
Stretching |
Hardness |
from |
more than |
until |
A100mm
% min. |
A11,3
% min. |
A
% min. |
HB
min. |
HB
max. |
HV
min. |
HV
max. |
M
|
|
4
|
-
|
80
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
R2002
|
|
8
|
-
|
80
|
200
|
(60)
|
-
|
-
|
30
|
-
|
-
|
-
|
-
|
H0652 |
|
8 |
- |
80 |
- |
- |
- |
- |
- |
65 |
90 |
70 |
95 |
R4405 |
|
4 |
- |
25 |
440 |
(350) |
- |
9 |
10 |
- |
- |
- |
- |
R4205 |
|
- |
25 |
50 |
420 |
(330) |
- |
- |
12 |
- |
- |
- |
- |
R4005 |
|
- |
50 |
80 |
400 |
(310) |
- |
- |
12 |
- |
- |
- |
- |
H1355 |
|
4 |
- |
80 |
- |
- |
- |
- |
- |
135 |
180 |
140 |
185 |
R4705 |
|
4 |
- |
25 |
470 |
(380) |
- |
7 |
8 |
- |
- |
- |
- |
R4505 |
|
- |
25 |
50 |
450 |
(360) |
- |
- |
10 |
- |
- |
- |
- |
H1505 |
|
4 |
- |
50 |
- |
- |
- |
- |
- |
150 |
- |
155 |
- |
2 Treated for solution treatment
5 Treated for solution treatment, cold working and age hardening |
|
Mechanical properties of wrought and raw bars for die forging
(EN 12165): |
State |
Nominal size of the straight section |
Hardness |
Tensile strength
Rm
N/mm˛
approx. |
Conventional elastic limit at 0,2 %
Rp0,2
N/mm˛
approx. |
Stretching
A%
approx. |
Diameter
mm |
Size on flat mm |
from |
until and included |
from |
until and included |
HB
min. |
HV
min. |
M |
All sizes |
|
|
|
|
|
H0502 |
6 |
80 |
6 |
60 |
50 |
50 |
(250) |
(150) |
(20) |
H1053 |
105 |
110 |
(370) |
(300) |
(15) |
2 Without age hardening
3 With age hardening |
|
Mechanical properties of sections and rectangular bars (EN 12167): |
Etat |
Sizes |
Tensile strength Rm N/mm˛ min. |
Conventional elastic limit at 0,2Rp0,2 N/mm² |
Stretching
A % |
Hardness |
Section |
Rectangular bars thickness mm |
>
at |
<
or = |
HB
min. |
HV
min |
M
|
All |
All |
|
|
|
|
|
R2005
|
-
|
3
|
60
|
200
|
(60)
|
(30)
|
-
|
-
|
H0655 |
- |
3 |
60 |
- |
- |
- |
65 |
70 |
R3603 |
- |
3 |
30 |
360 |
(250) |
(15) |
- |
- |
H1053 |
- |
3 |
30 |
- |
- |
- |
105 |
110 |
R4204 |
- |
3 |
30 |
420 |
(350) |
(8) |
- |
- |
H1204 |
- |
3 |
30 |
- |
- |
- |
120 |
125 |
3 Treated for solution treatment and precipitation hardening
4
Treated for solution treatment, cold working and precipitation hardening
5
Treated for solution treatment |
|