Moderating elastic limit and high electrical and heat conductivities.
|
Chemical compound % |
Agent |
Cu |
Be |
Co |
Cr |
Fe |
Mn |
Ni |
Pb |
Si |
Zr |
Other |
Mass-volume g/cm3 |
Mini: |
Reste
|
0,4
|
0,8
|
-
|
-
|
-
|
0,8
|
-
|
-
|
-
|
-
|
8,8
|
Maxi: |
-
|
0,7
|
1,3
|
-
|
0,2
|
-
|
1,3
|
-
|
-
|
-
|
0,5
|
|
|
Mechanical properties of forging parts (EN 12420): |
State |
Hardness HB min. |
Tensile strength Rm N/mm² min. |
Conventional elastic limit at 0,2Rp0,2 N/mm² min. |
Stretching A % min. |
H210*
|
210
|
(650)
|
(500)
|
(8)
|
*
Annealing of solution treatment and precipitation hardened |
|
Mechanical properties of plates, sheets and coils for general usings (EN1652): |
State |
Thickness |
Tensile strength Rm N/mm˛ |
Conventional elastic limit at 0,2 Rp0,2 N/mm² . |
Stretching |
Hardness
HV |
From |
to |
min. |
max. |
A50mm
ep < or = 2,5 |
A
ep > 2,5 |
min. |
max. |
R2401
|
1
|
15
|
240
|
-
|
(max.
220) |
20
|
20
|
-
|
-
|
H0601
|
1
|
15
|
-
|
-
|
-
|
-
|
-
|
60
|
130
|
R4801 |
1 |
15 |
480 |
- |
(min.
370) |
2 |
2 |
- |
- |
H1401 |
1 |
15 |
- |
- |
- |
- |
- |
140 |
180 |
R6502 |
1 |
15 |
650 |
- |
(min.
500) |
8 |
8 |
- |
- |
H2002 |
1 |
15 |
- |
- |
- |
- |
- |
200 |
280 |
R7502 |
1 |
15 |
750 |
- |
(min.
650) |
5 |
5 |
- |
- |
H2102 |
1 |
15 |
- |
- |
- |
- |
- |
210 |
290 |
1
Heat treatment in solution and cold rolling
2
Heat treatment in solution, cold rolling and age hardening in manufacture. |
|
Mechanical properties of bars for general usings (EN 12163): |
State |
Implementation |
Diameter or size/flats mm |
Tensile strength Rm N/mm˛ min. |
Conventional elastic limit at 0,2 Rp0,2 N/mm² |
Stretching |
Hardness |
from |
more than |
until |
A100mm
% min. |
A11,3
% min. |
A
% min. |
HB
min. |
HB
max. |
HV
min. |
HV
max. |
M
|
|
2
|
-
|
80
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
R25002
|
|
2
|
-
|
80
|
250
|
(140)
|
25
|
22
|
25
|
-
|
-
|
-
|
-
|
H0652 |
|
2 |
- |
80 |
- |
- |
- |
- |
- |
65 |
95 |
70 |
100 |
R5003 |
|
2 |
- |
25 |
500 |
(430) |
5 |
6 |
8 |
- |
- |
- |
- |
H1353 |
|
2 |
- |
25 |
- |
- |
- |
- |
- |
135 |
175 |
140 |
180 |
R4503 |
|
- |
25 |
40 |
450 |
(380) |
- |
- |
10 |
- |
- |
- |
- |
H1253 |
|
- |
25 |
40 |
- |
- |
- |
- |
- |
125 |
175 |
130 |
180 |
R4003 |
|
- |
40 |
80 |
400 |
(330) |
- |
- |
10 |
- |
- |
- |
- |
H1103 |
|
- |
40 |
80 |
- |
- |
- |
- |
- |
110 |
160 |
115 |
165 |
R6504 |
|
2 |
- |
80 |
650 |
(500) |
8 |
10 |
12 |
- |
- |
- |
- |
H1904 |
|
2 |
- |
80 |
- |
- |
- |
- |
- |
190 |
- |
200 |
- |
R8005 |
|
2 |
- |
25 |
800 |
(730) |
(3) |
(4) |
5 |
- |
- |
- |
- |
H2205 |
|
2 |
- |
25 |
- |
- |
- |
- |
- |
220 |
- |
230 |
- |
R7505 |
|
- |
25 |
40 |
750 |
(680) |
- |
- |
5 |
- |
- |
- |
- |
H2105 |
|
- |
25 |
40 |
- |
- |
- |
- |
- |
210 |
- |
220 |
- |
R7005 |
|
- |
40 |
80 |
700 |
(630) |
- |
- |
5 |
- |
- |
- |
- |
H2005 |
|
- |
40 |
80 |
- |
- |
- |
- |
- |
200 |
- |
210 |
- |
2
Treated for solution treatment
3
Treated for solution treatment and cold working
4
Treated for solution treatment and age hardening
5
Treated for solution treatment, cold working and age hardening |
|
Mechanical properties of wrought and raw bars for die forging
(EN 12165): |
State |
Nominal size of the straight section |
Hardness |
Tensile strength
Rm
N/mm˛
approx. |
Conventional elastic limit at 0,2 %
Rp0,2
N/mm˛
approx. |
Stretching
A%
approx. |
Diameter
mm |
Size on flat mm |
from |
until and included |
from |
until and included |
HB
min. |
HV
min. |
M |
All sizes |
|
|
|
|
|
H0602 |
6 |
80 |
6 |
60 |
60 |
65 |
(300) |
(200) |
(20) |
H2203 |
220 |
230 |
(650) |
(550) |
(8) |
2
Without age hardening
3
With age hardening |
|
Mechanical properties of wires (EN 12166) : |
State |
Diameter |
Tensile strength Rm N/mm˛ |
Conventional elastic limit at 0,2Rp0,2 N/mm² |
Stretching |
Hardness
HV |
from |
more than |
until |
min. |
Max. |
A100mm
% min. |
A11,3
% min. |
A
% min. |
min. |
max. |
R2403
|
1,0
|
-
|
10,0
|
240
|
380
|
(135)
|
15
|
18
|
20
|
-
|
-
|
H0903 |
1,0 |
- |
10,0 |
- |
- |
- |
- |
- |
- |
90 |
- |
R4404 |
1,0 |
- |
10,0 |
440 |
560 |
(445) |
- |
- |
(2) |
- |
- |
H1254 |
1,0 |
- |
10,0 |
- |
- |
- |
- |
- |
- |
125 |
- |
R6805 |
1,0 |
- |
10,0 |
680 |
900 |
(635) |
6 |
8 |
10 |
- |
- |
H2155 |
1,0 |
- |
10,0 |
- |
- |
- |
- |
- |
- |
215 |
- |
R7506 |
1,0 |
- |
10,0 |
750 |
970 |
(760) |
6 |
8 |
10 |
- |
- |
H2306 |
1,0 |
- |
10,0 |
- |
- |
- |
- |
- |
- |
230 |
- |
3
Treated for solution treatment
4 Treated for solution treatment and cold working
5 Treated for solution treatment and age hardening
6 Treated for solution treatment, cold working and age hardening |
|
Mechanical properties of sections and rectangular bars (EN 12167): |
State |
Sizes |
Tensile strength Rm N/mm˛ min. |
Conventional elastic limit at 0,2Rp0,2 N/mm² |
Stretching
A % |
Hardness |
Section |
Rectangular bars thickness mm |
>
at |
<
or = |
HB
min. |
HV
min |
M
|
All |
All |
|
|
|
|
|
R240
|
-
|
3
|
60
|
240
|
(130)
|
(25)
|
-
|
-
|
H055 |
- |
3 |
60 |
- |
- |
- |
55 |
60 |
R4402 |
- |
3 |
60 |
440 |
(340) |
(12) |
- |
- |
H1002 |
- |
3 |
60 |
- |
- |
- |
100 |
105 |
R6803 |
- |
3 |
30 |
680 |
(600) |
(15) |
- |
- |
H2203 |
- |
3 |
30 |
- |
- |
- |
220 |
230 |
R7504 |
- |
3 |
30 |
750 |
(700) |
(15) |
- |
- |
H2404 |
- |
3 |
30 |
- |
- |
- |
240 |
250 |
2 Treated for solution treatment and cold working
3 Treated for solution treatment and precipitation hardening
4 Treated for solution treatment, cold working and precipitation hardening |
|